We offer product training courses and guides to give you the skills and knowledge you need to operate your clinical laboratory instruments.
See all product training courses and guides ›
DxH 900 Hematology Analyzer
The DxH 900 hematology analyzer delivers accurate and high-confidence results on the first run. With its best-in-class hematology technology, this automated analyzer minimizes slide reviews, maximizes laboratory staff time, and provides significant cost savings. The DxH 900 offers scalable, customized solutions to address the hematology testing needs of high-volume labs.
Monocyte Distribution Width
Exclusive to the DxH 900 and 690T analyzers is the regulatory-cleared hematological biomarker Monocyte Distribution Width (MDW).3 Available as part of the CBC-diff, MDW aids physicians in identifying risk of severe of infection and sepsis in adult Emergency Department patients.
Quality That Counts
Trust your results—the first time—with high-quality hematology analyzers that deliver precise, accurate results and advanced cellular insights.
- Achieve superior RBC, PLT and WBC differentials through near native-state cellular characterization
- Deliver high-confidence results on the first run—minimizing reruns and reflex tests
- Improve slide interpretation with intelligent technology that helps optimize smearing, ensuring consistent slide quality
Productivity That Liberates
Free up your busy laboratory’s hematology team and empower your staff to focus on samples and tasks that truly need attention
- Simplify workload planning with predictable hematology workflows that let you save time for the unexpected
- Optimize your limited resources with reliable flagging
Savings That Empower
Tap into powerful savings to help your lab devote time, budget, and resources where they are needed most
- Streamline QA/QC processes through customizable, automated technology with daily reminders and remote support
- Save time, reduce costs, and optimize hematology instrument usage with fewer reflex tests
o Reduce hematology reagent use and associated costs
o Reallocate up to 200 minutes of daily run-time previously spent on reflex testing1
o Reduce overhead costs like electricity and maintenance
Webinar Full-Field & Fully Digital: The Future of Digital Hematology
Watch this on-demand webinar to hear Robin Johnson lab director at Vista Clinical Diagnostics and and Ahmed Bentahar medical director at Beckman Coulter as they discuss how digital hematology solutions are improving lab performance.
Register hereCasebook Digital Hematology: Advanced Technology Guide
With its advanced theory of operation and near-native cellular characterization, DxH 900 & 690T hematology analyzer technology allows for effective cellular analysis to accurately analyze blood cells and provide clinically significant data to aid in disease identification. Download the casebook to learn more.
Download casebookMonocyte Distribution Width
Exclusive to the DxH 900 and 690T analyzers is the regulatory-cleared hematological biomarker Monocyte Distribution Width (MDW) that aids physicians in identifying severity of infection and risk of sepsis in adult Emergency Department patients. This marker is available early in patient assessment as part of a CBC-Diff test with no impact to workflow.
Learn moreVideo Impact in Improving Patient Outcomes
Discover how our hematology analyzers has made a huge impact in improving patient outcomes for Patusa Mayfield, Director of Laboratory Services at Christus® Trinity Mother Frances Health System.
Watch video
Blog
Concentrating on Our Planet
We are dedicated to protecting our natural resources through new laboratory innovation—positively impacting the world around us. Learn how we’re fulfilling this promise with our new DxH Concentrated ECO Diluent.
Read blogTechnical Specifications
Methodology |
Enhanced Coulter Principle, VCS 360 with DataFusion |
|||||
Parameters |
CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC #, MDW (when enabled) Retic: RET, RET#, MRV, IRF Body Fluids (Cerebrospinal, Serous, or Synovial): RBC, TNC |
|||||
Throughput (tests per hour) |
Up to 100 samples/hour |
|||||
Sample Volumes |
165 μL aspiration volume; 0.5 ml dead volume. Predilute: 50 μL whole blood into 200 μL of diluent |
|||||
Analytical Measuring Ranges2 |
Whole Blood (CBC) |
|||||
Parameters |
Units |
Analytical Measuring Range |
||||
WBC |
x103 cells/μL |
0.050–400.000 |
||||
RBC |
x106 cells/μL |
0.005–8.500 |
||||
HGB |
g/dL |
0.10–25.50 |
||||
MCV |
fL |
50.00–150.00 |
||||
RDW |
% |
10.00–40.00 |
||||
RDW-SD |
fL |
15.00–150.00 |
||||
PLT |
x103 cells/μL |
3.0–3000.0 |
||||
MPV |
fL |
5.00–25.00 |
||||
Body Fluids |
||||||
TNC |
cells/mm3 |
20–89,000 |
||||
RBC |
cells/mm3 |
1,000–6,200,000 |
||||
Data Management |
Up to 50,000 patient results with histograms, scatter plots, and demographics 100,000 patient results with graphics for power computer |
|||||
Quality Assurance |
QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC |
|||||
Acoustic Noise Level |
≤ 60 dBa |
|||||
Radio Frequency and Interference Immunity |
Meet the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use—EMC Requirements), and EN 61326-2-6 (Part 2, Specific Requirements for In-Vitro Diagnostic Devices) |
|||||
Power Consumption |
DxH 900 SPM: 520 W (1775 BTU/hour), Monitor: 35 W (120 BTU/hour), DxH Power Computer: 160 W (546 BTU/hour) |
|||||
Dimensions and weight3 |
Width |
Height |
Depth |
Weight |
||
76.2 cm (30 in.) |
176.53 cm (69.5 in.), with cover closed 199.39 cm (78.5 in.), with cover open |
83.82 cm (33 in.), including the removable back panel 80 cm (31.5 in.), excluding the removable back panel |
~292.11 kg (644 lbs.), ~287.12 kg (633 lbs.), |
|||
Additional Clearance |
15.2 cm (6.0 in.) per side of instrument for troubleshooting; 3.8 cm (1.5 in.) behind instrument for sufficient cooling |
Maintenance and Troubleshooting
Service |
New Preventative Maintenance (PM) schedule with customer care visits |
Support |
Onboard IFU and Instructional Videos, Automated QC and calibration reminders, PROService |
Analyzer Downtime |
Minimum of 30 minutes in cleaner every 24 hours with automatic daily checks |
Research Use Only Parameters
Available RUO Parameters4 |
BFM, BFM#, BFP, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to reference 4 for additional RUO parameters) |
Research Use Only. Not for use in In Vitro Diagnostic procedures.
2. DxH 900 IFU (PN C06947.AD)
3. DxH 900 ReadMe (PN C53971.AB)
4. DxH 900 RUO Addendum
Tips & Tools
- DxH 520 Implementation Workbook
- DxH 520 Instrument Maintenance Checklist
- Hematology Performance Verification Guide
- Unicel DxH Series 600 & 800 Competency Checklist
- Unicel DxH Series Cleaning Checklist
- DxH New Features
- DXH Series Competency Checklist
- Unicel DxH Workcell Settings
- BD MAP Tubes Tech Tips
- Loading Diluent in the Wrong Position
- Tech Tip DxH LIN-X Using the Studies Mode
- Tech Tip DxH LIN-X
- Tech Tip UniCel DxH Downtime Procedure
- UniCel DxH Connectivity Settings
- Unicel DxH Series IQAP Information Guide Hematology
Educational Resources
1. Data drawn from side-by-side evaluation of flagging performance and low confidence results (R for DxH - Beckman Coulter and * for XN - Sysmex), based on 11 hospitals and N=1633 samples. View potential savings model report.
2. Serrando Querol M, Nieto-Moragas J, Marull Arnall A, Figueras MD, Jiménez-Romero O. Evaluation of the New Beckman Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency. Diagnostics (Basel). 2021;11(10). doi:10.3390/diagnostics11101756.
Beckman Coulter is a distributor of Scopio Labs and RR Mechatronics products. RPI water purification system is manufactured by the Life Science business of Merck KGaA, Darmstadt, Germany. The Life Science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.