Posters

Access a variety of scientific posters detailing findings and developments in clinical laboratory research.

Poster Comparison of Platelet Counting between the DxH 900, Sysmex XN, and Scopio

Without the right analyzer, getting an accurate platelet count can be tricky. Here, scientists compared platelet counts using three different methods to understand how the hematology analyzers stack up.

Download Poster
Levin poster image

Poster Unlocking the CBC with Monocyte Distribution Width (MDW): A Global, Single-panel Lab Sepsis Screening Tool

Learn how scientists from Johns Hopkins School of Medicine, University of Kansas School of Medicine, and Beckman Coulter derived the CBC Index—a simple 5-point scale including MDW—to estimate the likelihood that an ED patient will develop sepsis.

Download Poster
Hinson SAEM Poster

Poster Unlocking the CBC: Using MDW to Create a Universal Sepsis Screening Tool

In this retrospective study, time to antibiotics was assessed in a cohort of patients presenting with vague, lower suspicion, or higher suspicion sepsis based on MDW values obtained in the CBC.

Download Poster

Poster Precision pipetting improves sample delivery

Learn how precision pipetting improves small-volume sample delivery for high sensitivity assays to conserve patient samples & eliminate sample carryover

Download Poster

Poster PrecisionVision Technology: The Future of Automated Immunoassay

Learn how advanced PrecisionVision Technology is improving process error monitoring in the DxI 9000 analyzer to give you a new level of confidence in your results.

Download Poster
MIC panel scientific poster

Poster MicroScan Meropenem/vaborbactam MIC Results Correlate with ISO/CLSI Reference Panels

Download the ECCMID 2020 poster for complete information showing the accuracy of meropenem/vaborbactam MIC panel results for Enterobacterales and P. aeruginosa correlated with frozen ISO/CLSI broth microdilution reference panel. Analyze the multicenter study’s methods, quality control parameters and conclusions based on EUCAST interpretive criteria.

Download Poster
MIC panel scientific poster

Poster Multicenter Evaluation of Cephalexin MIC Results for Enterobacterales

Download the ECCMID 2020 poster for complete information demonstrating that cephalexin MIC results for Enterobacteriales correlate well with the MICs obtained using frozen reference panels. Review details from this multicenter study which used EUCAST interpretive criteria.

 

Download Poster
Performance of DxH 520* Hematology Analyzer in Pediatric Populations

Poster Small Analyzer Meets Test-result Requirements for Children

See how two hematology analyzers—the DxH 520 and the DxH 800—correlate when analyzing pediatric samples, ranging from neonatal to adolescent.

Download
The Diagnostic Ability of Monocyte Distribution Width is Not Affected in Patients with Hematological Malignancy or Neutropenia*

Poster Novel Parameter Unaffected by Hematological Malignancy or Neutropenia

Discover how monocyte distribution width (MDW) detects sepsis early for emergency department patients. This multicenter study establishes that the novel MDW parameter performs equally well for patients with and without hematological malignancy and neutropenia.

Download
DxH 520* Analyzer Can Help to Identify Whole Blood Samples from Patients with Leukemia and Lymphoma

Poster DxH 520 Identifies Leukemia and Lymphoma Samples Needing Further Analysis

See results showing DxH 520 hematology analyzer flagging identified samples for reflex testing for leukemia and lymphoma diagnosis as accurately as manual methods.

Download
Multicenter Evaluation of Eravacycline MIC Results for E. coli Using MicroScan Dried Gram Negative MIC Panels

Poster Multicenter Evaluation:
Eravacycline MIC Results—EUCAST

View data from a study that demonstrated the accuracy of the eravacycline MIC for E. coli using MicroScan Dried Gram-negative MIC panels.

Download
Multicenter Evaluation of Meropenem/Vaborbactam MIC Results for Enterobacteriaceae Using MicroScan Dried Gram Negative MIC Panels

Poster Multicenter Evaluation: Meropenem/Vaboractam MIC Results—CLSI

See the correlation of results between the meropenem/vaboractam MIC for Enterobacteriaceae using MicroScan Dried Gram-negative MIC panels.

Download
Multicenter Evaluation of Ceftolozane/Tazobactam MIC Results for Enterobacteriaceae and Pseudomonas aeruginosa Using MicroScan Dried Gram Negative MIC Panels

Poster Multicenter Evaluation: Ceftolozane/Tazobactam MIC Results—EUCAST

Find out how results correlated between the ceftolozane/tazobactam MIC for Enterobacteriaceae and Pseudomonas using MicroScan Dried Gram-negative MIC panels.

Download
Poster presented at ASM Microbe 2019 - multicenter study to evaluate the accuracy of the EUCAST formulation of amoxicillin/clavulanic acid on a MicroScan Dried Gram Negative MIC Panels

Poster Multicenter Evaluation of EUCAST Amoxicillin/Clavulanic Acid on MicroScan Panels

An ASM 2019 poster that illustrates how MicroScan Dried Gram-negative MIC panels correlated to the EUCAST amoxicillin/clavulanic acid formulation with frozen ISO/CLSI microbroth reference panel results for Enterobacteriaceae. Review details from a multicenter study showing clear breakpoint agreement with one of the world’s most commonly used antimicrobial susceptibility guidelines.

Download
Poster presented at ASM Microbe 2019 - Multicenter Evaluation of Eravacycline MIC  Results for Enterobacteriaceae Using MicroScan  Dried Gram-negative MIC Panels

Poster MicroScan Eravacycline MIC Results Correlate with CLSI/ISO Frozen Panels

An ASM 2019 poster showing that the MicroScan Dried Gram-negative MIC panel results for eravacycline correlated well with frozen ISO/CLSI reference panels using FDA interpretive criteria. Analyze the multicenter study’s methods, quality control parameters and conclusions highlighting how panels compared with the frozen CLSI broth microdilution reference panel.

Download
EuroMedLab 2019 Scientific Poster: Analytical Performance Characteristics of Access PCT

Poster Analytical Performance Characteristics of Access PCT

Review the evidence demonstrating strong correlation and concordance of the Access PCT immunoassay to a well-established PCT predicate method. Showcased at EuroMedLab 2019, this clinical laboratory study confirms the precision and reproducibility of Access PCT assay results, which are returned within 20 minutes.

Download
EuroMedLab 2019 Scientific Poster: Access AMH Assay Results Reinforce Importance of Population-specific Reference Intervals

Poster Access AMH Assay Results Reinforce Importance of Population-specific Reference Intervals

Evaluate the results from a study of age-specific reference intervals (RIs) for anti-Müllerian hormone (AMH) levels in Russian women and men, which was showcased at EuroMedLab 2019. See how the newly derived RIs compare to those provided by the Access AMH assay manufacturer, which also includes Brazilian study data. These results reinforce the importance of obtaining population-specific RIs for each country.

Download
EuroMedLab2019 Scientific Poster:EuroMedLab2019 Scientific Poster: Access AMH Assay Reveals Temperatures Don’t Alter Anti-Müllerian Hormone Stability

Poster Access AMH Assay Reveals Temperatures Don’t Alter Anti-Müllerian Hormone Stability

Review the study-results revealed at EuroMedLab 2019 that show how broad temperature ranges produce no significant anti-Müllerian hormone (AMH) changes. This poster illustrates how one-to-five freeze-thaw cycles, four different temperature levels and multiple fresh-to-frozen storage conditions didn’t alter the molecule’s stability, which demonstrates the high sensitivity and precision of the Access AMH assay across diverse environments.

Download
Body Fluids Analysis iQ200 Poster

Poster Automated Body Fluid Analysis vs. Manual Microscopy

A study by clinical chemist Sorin Gîju, Ph.D., compared images of analyzed body fluid particles captured with the iQ200 series’ Digital Flow Morphology to those obtained via manual microcopy using filters on identical patient samples. Explore Dr. Gîju’s findings and the correlation between manual and digital methods.

Download
Hematology Analyzer Cell Development Poster

Poster Hematology: Stages of Human Blood Cell Development

View detailed illustrations of hematopoiesis. Learn the stages of human blood cell development, and see how red and white blood cells diverge along their paths from stem cells to their specialty forms like lymphocytes, neutrophils, thrombocytes and platelets.

Download

Poster Evaluation of the Analytic Performance of the New Beckman Coulter DxC 700 AU Clinical Chemistry System

Review the evidence finding that the DxC 700 AU chemistry analyzer demonstrates performance comparable to that of the AU680 and AU5800 analyzers.

Download
Urine Sediment Particles Can't hide from Iris

Poster Urine Sediment Particles Can't hide from Iris

Review details about how iRICELL Digital Flow Morphology automated urine microscopy imaging directly correlates to the gold standard manual method.

Download
2018 ASM Ceftazidime Avibactam Multicenter study

Poster The Accuracy of MicroScan Panels in Ceftazidime/Avibactam MIC Testing 

Discover the accuracy of MicroScan panels in testing the new antibiotic ceftazidime/avibactam, used to treat multidrug-resistant Gram-negative infections.

Download
2018 ASM Ceftolozane Poster

Poster Evaluation of Ceftolozane/Tazobactam MIC Testing Using MicroScan Panels

Learn about the reliable performance of MicroScan panels in testing new drug ceftolozane/tazobactam for multidrug-resistant Gram-negative infections.

Download
2018 ASM MicroScan Ciprofloxacin S Poster

Poster Expanded Ciprofloxacin MIC Testing Using MicroScan Panels

Review study results showing how MicroScan Panels support new requirements for testing typhoidal Salmonella strains from extraintestinal sources.

Download

Poster Development and Management of a New Core Lab Automation System

Discover S. Stefano Hospital's work in comparing the performance of Power Processor and Power Express automation systems and how automation enabled higher consolidation levels for tests, supported increased workload and drove an overall reduction in TAT. 

Download

Poster ISLH: Quality Control for Integrated Hematology

Check out how DxONE Insights delivers the ability to access quality control data and related instrument data from across a multi-instrument network from a single dashboard, increasing efficiency, maximizing uptime and aiding in the assurance of reporting quality results.

Download
Multicenter evaluation of Imipenem MIC results at 18 hours for Gram-Negative organisms using MicroScan Dried Gram Negative MIC panels

Poster Verified Results at 18 Hours for Imipenem Testing from a Multicenter Study

Discover the results of a revised formulation of imipenem tested using MicroScan Dried Gram-negative MIC panels.

Download
Products referenced may not be available in all countries. Contact your local Beckman Coulter representative for availability.

1Kalorama United States Market for In Vitro Diagnostic Tests, 2017, pg. 878.