| Liquid Handling |
Volume Range
Pipetting Module (5 μL to 1,000 μL)
Syringe Pump Size
Aspiration/Dispense pump 2mL
Wash/Prime pump 5 mL
IMMUNOPREP reagents A, B, C 2 mL
Flow-Count pump 2 mL |
| Specimen Size |
5 μL to 1,000 μL (Volumes over 100 μL are delivered in multiple aliquots. Maximum aliquot volume is 100 μL) |
| Specimen Tube Size |
10 to 13 mm tubes
3 mL (10.25 x 64 mm) pediatric tubes
2 mL (13 x 47 or 50 mm) pediatric tubes |
| Specimen Tube Types |
Becton Dickinson Vacutainer* Tubes Worldwide
Becton Dickinson Glass Tubes with Hemogard*
Closure
Sarstedt
Sherwood Medical Tubes (Monoject) |
| Specimen Cassette Sizes |
Two sizes:
13 mm diameter tubes control tubes and pediatric size tubes in adaptors
16 mm diameter tubes |
| Carousel Tubes (Daughter Tubes) |
12 x 75 mm straight polypropylene or polystyrene test tubes |
| Bar Code Symbologies |
(Sample Identification)
Code 128 (USD-6)
Code 39
Interleaved 2 of 5 (also known as 12 of 5, USD-1 and USD-3)
Codabar (also known as USD-4 and NW7)
|
| System Performance Accuracy (by weight) |
| |
Specification |
Example Study Data |
10 μL |
9-12 μL |
0.011 |
20 μL |
18-22 μL |
0.021 |
50 μL |
47-53 μL |
0.050 |
100 μL |
95-105 μL |
0.098 |
|
| Precision |
| |
Specification (%CV) |
Example Study Data(%CV) |
10 μL |
CV<10% |
1.94% |
20 μL |
CV<10% |
2.51% |
50 μL |
CV<5% |
1.73% |
100 μL |
CV<5% |
1.05% |
|
| Carryover |
| |
Range |
Example Study Data |
Fluorescence |
<1% |
0.0% |
Primary Blood Sample |
<1% |
<0.08% |
|
| Throughput |
>80 daughter tubes per hour
Example data: 90 daughter tubes per hour in batch mode with tetraCXP (approx. 3 carousels per hour) |
| FP 1000 |
Height: 82 cm
(32 in)
Width: 123 cm
(48 in)
Depth: 77 cm
(30 in)
Weight: 91 kg
(200 lb)
|
| Computer |
Height: 15.9 cm
(6.2 in)
Width: 53.9 cm
(21 in)
Depth: 43.0 cm
(16.8 in)
Weight: 18.1 kg
(40 lb) |
| Monitor |
Height: 43.1 cm
(16.8 in)
Width: 40.8 cm
(15.9 in)
Depth: 44.3 cm
(17.3 in)
Weight: 22 kg
(48.4 lb) |
| Power Requirements |
Installation Category - Over voltage Category II
Input Voltages - 100/240 Vac
Frequency - 48/62 Hz
Maximum Power - 150 W |
| Noise |
≤ 65 db |
| Operating Temperatures |
16 to 32° C (60 to 90° F) |
| Operating Humidity Range |
30% to 85%, without condensation |
| Safety |
UL, CSA and CE |
| Pollution |
Degree 2 |
| Altitude |
Up to 2,000 m |
| Workstation Computer |
Intel* Pentium* 4 microprocessor |
| Data Storage |
3.5 in, 1.44 MB diskette drive
40 GB hard disk
52x (or higher) CD-ROM drive, MPCII compatible
750 MB ZIP* drive |
| Interfaces |
Windows* 2000 SP4
Bidirectional asynchronous serial interfaces for communication with mainframes and personal computers via Data Innovation's Instrument Manager* |
| Monitor |
SVGA flat-screen 17 inch color monitor |
| Communications |
One parallel port
Two USB ports
Onboard Ethernet network interface |
| Input Devices |
PS/2 optical IntelliMouse*
Standard IBM*-AT compatible 102 keyboard
Chumoto hand held bar code reader |